Hager MCB Circuit Breaker  MCN363 6KA 3pole, 63A

Product Data Sheet
MCN363
Technical subject to change
MCB 3P 6kA C-63A 3M
Technische Merkmale
Architecture
Neutral position without neutral
Number of protected poles 3
Number of poles 3 P
Type of pole 3 P
Fixing mode Din-Rail
Curve C
Controls and indicators
With fault indicator no
Connectivity
Bottom connection alignement for modular devices Aligned terminal
Top connection alignement for modular devices Aligned terminal
Main electrical features
Frequency 50/60 Hz
Rated short circuit breaking capacity Icn AC
according IEC60898-1
6 kA
Type of supply voltage AC
Rated operational voltage Ue 415 V
Voltage
Rated insulation voltage 500 V
Rated impulse withstand voltage 4000 V
Electric current
Rated short circuit breaking capacity Icn under
400V AC according IEC60898-1
6 kA
Rated service breaking capacity Ics AC according
IEC 60898-1
6 kA
Magnetic regulating currrent at 40° C 5/10 In
min/maxi threshold value of the AC thermal
operation
1,13/1,45 In
MCN363
Product Data Sheet
MCN363
Technical subject to change
Electric current / temperature
Rating current -15°C 75,55 A
Rating current -20°C 76,96 A
Rating current 0°C 71,3 A
Rating current 10°C 68,46 A
Rating current -10°C 74,06 A
Rating current 15°C 67,05 A
Rating current 20°C 65,63 A
Rating current 25°C 64,21 A
Rating current -25°C 78,38 A
Rating current 30°C 63 A
Rating current 35°C 61,38 A
Rating current 40°C 59,97 A
Rating current 45°C 58,55 A
Rating current 5°C 69,88 A
Rating current -5°C 72,71 A
Rating current 50°C 57 A
Rating current 55°C 55,72 A
Rating current 60°C 54,3 A
Rating current 65°C 52,88 A
Rating current 70°C 51,47 A
Current correction factors
Correction factor of magnetic tripping with 100 Hz 1,1
Correction factor of magnetic tripping with 200 Hz 1,2
Correction factor of magnetic tripping with 400 Hz 1,5
Correction factor of magnetic tripping with 60 Hz 1
Correction factor of rating current for 2 devices
placed side-by-side
1
Correction factor of rating current for 3 devices
placed side-by-side
0,8
Correction factor of rating current for 4 and 5
devices placed side-by-side
0,7
Correction factor of rating current for 6 devices
placed side-by-side
0,6
Power
Power loss per pole at In 6,43 W
Total power loss under IN 18,27 W
Endurance
Electric endurance in number of cycles 4000
Number of mechanical operations 20000
Dimensions
Depth of installed product 70 mm
Height of installed product 84,6 mm
Width of installed product 52,5 mm
Product Data Sheet
MCN363
Technical subject to change
Installation, mounting
Type of top connection for modular devices with screw
Tightening torque 2,8Nm
Type of bottom rail clip for modular devices plastic
Type of top rail clip for modular devices NA
Type of Bottom Connection for modular devices BIconnect
Bottom removability for modular devices yes
Top removability for modular devices no
Connection
Connection cross-sect. rigid cable 1 / 35mm²
Connection cross-sect. flexible conductor 1 / 25mm²
Type of connection with screw
Connection cross section of access and exit with
screws, for flexible conductor
1/25 mm²
Connection cross-section of input and output with
screws, for massive conductors
1/35 mm²
Equipment
Quick connect no
Standards
Standard text IEC 60898-1
European directive WEEE not concerned
Safety
Protection index IP IP20
Use conditions
Degree of pollution according to IEC 60664 / IEC
60947-2
2
Operating temperature -25 … 70 °C
Class of energy limitation I²t 3
Altitude 2000 m
Storage temperature -25 to 80 °C
Air humidity protection for all climates
Storage/transport temperature -25 … 80 °C
Powered by TCPDF (www.tcpdf.org)

Reviews

There are no reviews yet.

Be the first to review “Hager MCB Circuit Breaker MCN363 6KA 3pole, 63A”

Your email address will not be published. Required fields are marked