Hager MCB Circuit Breaker MCN110 6KA 1pole, 10A

Product data sheet
MCN110
1 Technical subject to change
MCN110
MCB 1P 6kA C-10A 1M
Architecture
Neutral position without neutral
Number of protected poles 1
Number of poles 1 P
Type of pole 1 P
Fixing mode Din-Rail
Curve C
Controls and indicators
With fault indicator no
Connectivity
Bottom connection alignement for modular devices Aligned terminal
Top connection alignement for modular devices Aligned terminal
Main electrical features
Frequency 50/60 Hz
Rated short circuit breaking capacity Icn AC according
IEC60898-1
6 kA
Type of supply voltage AC
Rated operational voltage Ue 240/415 V
Voltage
Rated insulation voltage 500 V
Rated impulse withstand voltage 4000 V
Electric current
Rated short circuit breaking capacity Icn under 230V
AC according IEC60898-1
6 kA
Rated service breaking capacity Ics AC according IEC
60898-1
6 kA
Magnetic regulating currrent at 40° C 5/10 In
min/maxi threshold value of the AC thermal operation 1,13/1,45 In
Product data sheet
MCN110
2 Technical subject to change
Electric current / temperature
Rating current -15°C 10,83 A
Rating current -20°C 10,98 A
Rating current 0°C 10,38 A
Rating current 10°C 10,07 A
Rating current -10°C 10,5 A
Rating current 15°C 9,92 A
Rating current 20°C 9,77 A
Rating current 25°C 9,62 A
Rating current -25°C 11,14 A
Rating current 30°C 10 A
Rating current 35°C 9,31 A
Rating current 40°C 9,16 A
Rating current 45°C 9,01 A
Rating current 5°C 10,22 A
Rating current -5°C 10,53 A
Rating current 50°C 8,5 A
Rating current 55°C 8,7 A
Rating current 60°C 8,55 A
Rating current 65°C 8,4 A
Rating current 70°C 8,25 A
Current correction factors
Correction factor of magnetic tripping with 100 Hz 1,1
Correction factor of magnetic tripping with 200 Hz 1,2
Correction factor of magnetic tripping with 400 Hz 1,5
Correction factor of magnetic tripping with 60 Hz 1
Correction factor of rating current for 2 devices placed
side-by-side
1
Correction factor of rating current for 3 devices placed
side-by-side
0,8
Correction factor of rating current for 4 and 5 devices
placed side-by-side
0,7
Correction factor of rating current for 6 devices placed
side-by-side
0,6
Power
Power loss per pole at In 1,81 W
Total power loss under IN 1,81 W
Endurance
Electric endurance in number of cycles 4000
Number of mechanical operations 20000
Dimensions
Depth of installed product 70 mm
Height of installed product 84,6 mm
Width of installed product 17,5 mm
Installation, mounting
Type of top connection for modular devices with screw
Tightening torque 2,8Nm
Type of bottom rail clip for modular devices plastic
Type of top rail clip for modular devices NA
Type of Bottom Connection for modular devices BIconnect
Bottom removability for modular devices yes
Product data sheet
MCN110
3 Technical subject to change
Technical Properties
Top removability for modular devices no
Connection
Connection cross-sect. rigid cable 1 / 35mm²
Connection cross-sect. flexible conductor 1 / 25mm²
Type of connection with screw
Connection cross section of access and exit with
screws, for flexible conductor
1/25 mm²
Connection cross-section of input and output with
screws, for massive conductors
1/35 mm²
Equipment
Quick connect no
Standards
Standard text IEC 60898-1
European directive WEEE not concerned
Safety
Protection index IP IP20
Use conditions
Degree of pollution according to IEC 60664 / IEC
60947-2
2
Operating temperature -25 … 70 °C
Class of energy limitation I²t 3
Altitude 2000 m
Storage temperature -25 to 80 °C
Air humidity protection for all climates
Storage/transport temperature -25 … 80 °C